Home Page | Manufacturers | Newmar | Phase Three | Quotation | Search | E-mail |
Phase Three "Specifications" |
12 Volt Models
|
|||||
PT-7
|
PT-14
|
PT-25
|
PT-40
|
PT-70A
|
Input VAC (50-60 Hz.) |
88-132 or 176-264
|
85-264
|
90-132 or 180-264
|
85-135 or 170-270
|
90-264
|
Input Amps @ Full Load @ 115 VAC |
2
|
2.8
|
6.5
|
8.5
|
12
|
Input Amps @ Full Load @ 230 VAC |
1
|
1.4
|
4
|
4.3
|
6
|
P.F. Rating |
>.65
|
.95@230V .98@115V
|
0.7
|
0.7
|
.95@230V .98@115V
|
Max Output Amps @ 115 VAC Input |
7
|
14
|
25
|
40
|
64
|
Max Output Amps @ 230 VAC Input |
7
|
14
|
25
|
40
|
70
|
Output Banks |
2
|
3
|
3
|
3
|
3
|
Battery Capacity (Amp-Hours) |
14-70
|
28-140
|
50-250
|
80-400
|
140-700
|
Operating Temp. Rating Reference |
T-2
|
T-2
|
T-2
|
T-1
|
T-2
|
Case Size Ref. |
A-1
|
A-2
|
A-2
|
A-3
|
A-5
|
Weight; Lbs./Kg. |
3.2/1.5
|
8/4
|
8.2/4
|
12/6
|
15.2/7
|
Optional Temp. Sensor Model |
N/A
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
Remote Panel Model |
N/A
|
RP
|
RP
|
RP
|
RP
|
Equalize Option |
No
|
Yes
|
Yes
|
Yes
|
Yes
|
Output Indicator Ref. |
M-2
|
M-1
|
M-1
|
M-1
|
M-1
|
Compliance Ref. |
CG, CE
|
CG, CE
|
CG
|
UL, CG, CE
|
CE
|
24
Volt Models
|
32
Volt
|
||||||
PT-24-8
|
PT-24-13
|
PT-24-20
|
PT-24-40
|
PT-24-45F
|
PT-24-95F
|
PT-32-30
|
Input VAC (50-60 Hz.) |
85-264
|
90-132 or 180-264
|
85-135 or 170-270
|
90-264
|
207-253
|
207-253
|
103-127
|
Input Amps @ Full Load @ 115 VAC |
2.8
|
6.5
|
8.5
|
12
|
N/A
|
N/A
|
11
|
Input Amps @ Full Load @ 230 VAC |
1.4
|
4
|
4.3
|
6
|
8
|
17
|
N/A
|
P.F. Rating |
.95@230V
.98@115V |
0.7
|
0.7
|
.95@230V
.98@115V |
0.7
|
0.7
|
0.7
|
Max Output Amps @ 115 VAC Input |
8
|
13
|
20
|
37
|
N/A
|
N/A
|
30
|
Max Output Amps @ 230 VAC Input |
8
|
13
|
20
|
40
|
45
|
95
|
NA
|
Output Banks |
3
|
3
|
3
|
3
|
3
|
3
|
3
|
Battery Capacity (Amp-Hours) |
16-80
|
26-130
|
40-200
|
80-400
|
90-450
|
180-950
|
60-300
|
Operating Temp. Rating Reference |
T-2
|
T-2
|
T-1
|
T-2
|
T-3
|
T-3
|
T-3
|
Case Size Ref. |
A-2
|
A-2
|
A-3
|
A-5
|
A-4
|
A-6
|
A-4
|
Weight; Lbs./Kg. |
8/4
|
8.2/4
|
12/6
|
15.2/7
|
12.2/6
|
34.0/15
|
12.2/6
|
Optional Temp. Sensor Model |
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TP
|
TP
|
TP
|
Remote Panel Model |
RP
|
RP
|
RP
|
RP
|
N/A
|
N/A
|
N/A
|
Equalize Option |
Yes
|
Yes
|
Yes
|
Yes
|
No
|
No
|
No
|
Output Indicator Ref. |
M-1
|
M-1
|
M-1
|
M-1
|
M-3
|
M-3
|
M-3
|
Compliance Ref. |
CG, CE
|
CG
|
UL, CG, CE
|
CE
|
EN, CE
|
EN, CE
|
EN, CE
|
Case Size
Reference
|
||||||
Inches
|
Centimeters
|
|||||
Ref |
Height
|
Width
|
Depth
|
Height
|
Width
|
Depth
|
A-1 |
10.5
|
5.0
|
2.8
|
26.7
|
12.7
|
7.1
|
A-2 |
12.5
|
7.7
|
4.3
|
31.8
|
19.6
|
10.9
|
A-3 |
14.1
|
9.5
|
4.0
|
35.8
|
24.1
|
10.2
|
A-4 |
15.5
|
9.7
|
5.0
|
39.4
|
24.6
|
12.7
|
A-5 |
15.7
|
9.8
|
6.7
|
39.9
|
24.9
|
17.0
|
A-6 |
19.5
|
12.2
|
8.2
|
49.5
|
40.0
|
20.8
|
Compliance References*: | Output Indicator References: | |||
UL | UL 1950 (Per DNB report) | M-1 | Total output ammeter | |
CG | USCG CFR 183.410 (Ignition protected) | M-2 | Charge/Float L.E.D. | |
EN | EN 60335-1, EN 60335-2-29 | M-3 | Total output ammeter and charger status L.E.D.'s/Alarms | |
CE | Carries the CE Mark | |||
* Numerous other Safety and EMC compliances may also apply. Contact factory if further compliance information is required. |
Temperature Rating References: | |
T-1 | -25�C to +60�C; Derate linearly from 100% @ 50�C to 75% @ 60�C |
T-2 | -10�C to +60�C; Derate linearly from 100% @ 50�C to 80% @ 60�C |
T-3 | -20�C to +50�C |
Nominal Output Voltages at Gel/Flooded Switch Settings | |||||||
12
Volt Models
|
24
Volt Models
|
32
Volt Models
|
|||||
Settings |
Charge @ 50% load
|
Float @ .5 amp load
|
Charge @ 50% load
|
Float @ .5 amp load
|
Charge @ 50% load
|
Float @ .5 amp load
|
|
Gel-Cell |
14.0 VDC
|
13.6 VDC
|
28.0 VDC
|
27.2 VDC
|
37.3
|
36.2
|
|
Flooded/AGM |
14.2 VDC
|
13.4 VDC
|
28.4 VDC
|
26.8 VDC
|
37.8
|
35.7
|
WISCO International, Inc. -
MIAMI, FL U.S.A. Fax: (954) 370-3997 | E-mail: wiscointl@wiscointl.com |