WISCO International

NEWMAR

Home Page | Manufacturers | Newmar | Phase Three | Quotation | Search | E-mail

Phase Three "Specifications"

12 Volt Models
 
PT-7
PT-14
PT-25
PT-40
PT-70A
Input VAC (50-60 Hz.)
88-132 or 176-264
85-264
90-132 or 180-264
85-135 or 170-270
90-264
Input Amps @ Full Load @ 115 VAC
2
2.8
6.5
8.5
12
Input Amps @ Full Load @ 230 VAC
1
1.4
4
4.3
6
P.F. Rating
>.65
.95@230V .98@115V
0.7
0.7
.95@230V .98@115V
Max Output Amps @ 115 VAC Input
7
14
25
40
64
Max Output Amps @ 230 VAC Input
7
14
25
40
70
Output Banks
2
3
3
3
3
Battery Capacity (Amp-Hours)
14-70
28-140
50-250
80-400
140-700
Operating Temp. Rating Reference
T-2
T-2
T-2
T-1
T-2
Case Size Ref.
A-1
A-2
A-2
A-3
A-5
Weight; Lbs./Kg.
3.2/1.5
8/4
8.2/4
12/6
15.2/7
Optional Temp. Sensor Model
N/A
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24
Remote Panel Model
N/A
RP
RP
RP
RP
Equalize Option
No
Yes
Yes
Yes
Yes
Output Indicator Ref.
M-2
M-1
M-1
M-1
M-1
Compliance Ref.
CG, CE
CG, CE
CG
UL, CG, CE
CE
24 Volt Models
32 Volt
 
PT-24-8
PT-24-13
PT-24-20
PT-24-40
PT-24-45F
PT-24-95F
PT-32-30
Input VAC (50-60 Hz.)
85-264
90-132 or 180-264
85-135 or 170-270
90-264
207-253
207-253
103-127
Input Amps @ Full Load @ 115 VAC
2.8
6.5
8.5
12
N/A
N/A
11
Input Amps @ Full Load @ 230 VAC
1.4
4
4.3
6
8
17
N/A
P.F. Rating
.95@230V
 .98@115V
0.7
0.7
.95@230V
 .98@115V
0.7
0.7
0.7
Max Output Amps @ 115 VAC Input
8
13
20
37
N/A
N/A
30
Max Output Amps @ 230 VAC Input
8
13
20
40
45
95
NA
Output Banks
3
3
3
3
3
3
3
Battery Capacity (Amp-Hours)
16-80
26-130
40-200
80-400
90-450
180-950
60-300
Operating Temp. Rating Reference
T-2
T-2
T-1
T-2
T-3
T-3
T-3
Case Size Ref.
A-2
A-2
A-3
A-5
A-4
A-6
A-4
Weight; Lbs./Kg.
8/4
8.2/4
12/6
15.2/7
12.2/6
34.0/15
12.2/6
Optional Temp. Sensor Model
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24
TP
TP
TP
Remote Panel Model
RP
RP
RP
RP
N/A
N/A
N/A
Equalize Option
Yes
Yes
Yes
Yes
No
No
No
Output Indicator Ref.
M-1
M-1
M-1
M-1
M-3
M-3
M-3
Compliance Ref.
CG, CE
CG
UL, CG, CE
CE
EN, CE
EN, CE
EN, CE
Case Size Reference
 
Inches
Centimeters
Ref
Height
Width
Depth
Height
Width
Depth
A-1
10.5
5.0
2.8
26.7
12.7
7.1
A-2
12.5
7.7
4.3
31.8
19.6
10.9
A-3
14.1
9.5
4.0
35.8
24.1
10.2
A-4
15.5
9.7
5.0
39.4
24.6
12.7
A-5
15.7
9.8
6.7
39.9
24.9
17.0
A-6
19.5
12.2
8.2
49.5
40.0
20.8
 
Compliance References*:   Output Indicator References:
UL UL 1950 (Per DNB report) M-1 Total output ammeter
CG USCG CFR 183.410 (Ignition protected) M-2 Charge/Float L.E.D.
EN EN 60335-1, EN 60335-2-29 M-3 Total output ammeter and charger status L.E.D.'s/Alarms
CE Carries the CE Mark  
* Numerous other Safety and EMC compliances may also apply. Contact factory if further compliance information is required.
Temperature Rating References:
T-1 -25�C to +60�C; Derate linearly from 100% @ 50�C to 75% @ 60�C
T-2 -10�C to +60�C; Derate linearly from 100% @ 50�C to 80% @ 60�C
T-3 -20�C to +50�C
(without Temperature Compensation option installed or at 22.2�C (72�F) with Temperature Compensation option installed):
Nominal Output Voltages at Gel/Flooded Switch Settings
 
12 Volt Models
24 Volt Models
32 Volt Models
Settings
Charge @ 50% load
Float @ .5 amp load
Charge @ 50% load
Float @ .5 amp load
Charge @ 50% load
Float @ .5 amp load
Gel-Cell
14.0 VDC
13.6 VDC
28.0 VDC
27.2 VDC
37.3
36.2
Flooded/AGM
14.2 VDC
13.4 VDC
28.4 VDC
26.8 VDC
37.8
35.7
WISCO International, Inc. - MIAMI, FL U.S.A.
Fax: (954) 370-3997 | E-mail: wiscointl@wiscointl.com