MODEL 807 |
|
MPT 1327 Single Site
Controller INTRODUCTION The MPT 1327 trunked mobile radio standard is internationally recognized for public and private radio systems. Zetron’s Model 807 Trunking Controller implements this standard in an economical, entry level controller package designed for single-site dispatch applications. Its modular design approach ensures a cost-effective system with the facility to add telephone interconnect at the site by connecting to a Model 827 controller fitted with the telephone interface option. BENEFITS CALL TYPES
Features TRUNKING CONTROLLER
TELEPHONE INTERCONNECT USING MODEL 827
|
|
Specifications |
| PHYSICAL | |
| Power | 10.5 to 16 Volts DC, 12 Watts |
| Temperature | 0 to 60 deg. Celsius |
| Size | 48.3 cm W x 4.5 cm H x 26.3 cm D |
| Weight | 3 Kg |
| RADIO Conforms to MPT 1327/1343 trunking standard. Supports radios compliant with MPT 1327/1352. Full-duplex or half-duplex operation. |
|
| RADIO INTERFACE | |
| PTT | Form-C relay closure 1 amp @ 30 volts max. |
| COR | External COR/CAS, polarity select, Internal Squelch |
| Tx Audio | Adjustable -40 to 3 dBm. 1K ohm impedance @ 1000hz |
| Rx Audio | Adjustable -40 to 3 dB. Single or differential input 50K ohm impedance @ 1000hz |
| Connector | 12 position detachable screw strip |
| Modulation | depends on transmitter |
| SITE CAPACITY | |
| Channels | 24 radio channels at a single site |
| Subscribers | 5,000 subscribers expandable to 8,000 |
| Groups | 2000 group identities |
| Fleets | 500 fleets |
| ACCOUNTING | |
| Record Types | Registration, status, mobile-to-mobile |
| Capacity | Minimum 3656 to a maximum of 7313 records stored internally. Actual record size depends on call type. |
| Stored Information | Called/Calling prefix and ID, start date/time, call duration, channel. |
| Filtering | Storage of registration and status records can be set to on or off. |
| ADDITIONAL | |
| Indicators | Repeater, PTT, COR, Alarm, Bus, Status (VOX detect, FFSK Rx, FFSK Tx, poll, sync, not used, not used, not used) |
| Data Retention | Retains data for over 8,000 hours when power is removed from unit. There is no drain on the battery when the unit is operating. |
| Real-Time Clock | Typically 10 year shelf-life. |
| Programming | Remote programming via
PC using M827Base Database Programming Software. Access via internal modem or local RS-232 port |
| Alarm Monitoring | 3 specific system alarms plus 3 nonspecific |
| Alarm Inputs | 0-5volts Active: ground Inactive: open circuit |
| Alarm Outputs | 100mA - 10 Volts Active: grounds control output, Inactive: control output open circuit. |
| APPROVALS CE Approved |
|
|