PL-1100 Series Specifications |
| General |
UHF model |
UHF model |
| Frequency Range |
8 Pre-programmed |
|
| Channels |
1 22 |
|
Channel Spacing |
25 / 12.5 kHz |
|
| PLL Step | 5.0 / 6.25 kHz 5.0 | |
| Channel Spread | 3.425 MHz | 3.425 MHz |
| Antenna Impedance | 50 W | |
| Operating Voltage |
7.2V DC Nominal |
|
|
Battery Life (with 750 mAh NiMH battery) w/optional 1350 NiMH battery |
14 Hours
(90-5-5 duty cycle) |
11 Hours
(90-5-5 duty cycle) 19 Hours (90-5-5 duty cycle) |
| Operating Temperature | -22°F to +140°F (-30° C to +60° C) | |
| Frequency Stability (-30° C to +60° C) |
± 5.0 ppm | |
| Dimensions (H x W x D) with battery |
4-7/8" x 2-1/4" x 1-1/4" (125 x 58 x 32 mm) |
|
|
Weight (with 750 mAh NiMH battery and antenna) |
13.6 oz. (380 gm) |
|
| FCC Identifier | O7KPL450 | O7KPL450A |
FCC Compliance |
Parts 22, 74, 90 |
Parts 22, 74, 90, 95 |
| Canada Certification Number | 3772196802A | 3772196802A |
|
RECEIVER (Measurements procedures made per ANSI/TIA/EIA-603) |
||
| Sensitivity (12 dB SINAD) |
.25 µV
@12.5 kHz |
|
| Selectivity |
>55 dB @12.5 kHz |
|
| Intermodulation |
55 dB @12.5 kHz |
60 dB @25 kHz |
| Spurious Response | 60 dB |
|
| Audio output |
500 mW (Int.) @ 8Ω; |
|
|
TRANSMITTER (Measurements procedures made per ANSI/TIA/EIA-603) |
||
| RF Output | 1 Watts |
2 Watts
|
| Spurious and Harmonics Emissions | 43 dB |
|
| Modulation |
16KOF3E, 11KOF3E |
|
| FM Hum and Noise |
>34 dB @ 12.5 kHz |
|
| Audio distortion |
< 5% |
|
|
MIL-STD methods / procedures The Maxon PL1145 and PL2245 are approved to the following: |
| Standard | 810F Method / Procedure |
| Rain (Watertightness) | 506.4 / Proc. II |
| Humidity | 507.4 / Proc. I |
| Blowing Dust | 510.4 / Proc. I |
| Vibration | 514.5 / Proc. I |
| Shock | 516.5 / Proc. I, IV |
| Specifications are subject to change without notice. |
|
Wisco